HIGH-POINT architectural fabrics deliver outstanding results against arctic temperatures, heat, humidity, UV rays, high winds, and environmental pollutants.
- HIGH-POINT's high thread count scrim prevents tears from spreading thoughout the fabric. A high thread count also delivers exceptional biaxial strength.
- HIGH-POINT fabrics also offer optimal fire protection, passing stringent international fire codes.
TYPICAL PROPERTY |
TEST METHOD |
STANDARD |
METRIC |
| Base Fabric |
|
Polyester |
Polyester |
| Fabric Weight |
ASTM D3776 |
5.0 oz/yd2 |
129 g/m2 |
| Weave Style |
|
Weft-Inserted |
Weft-inserted |
| UV Topcoat |
|
Polyurethane |
Polyurethane |
Finished Fabric
Weight
Width |
ASTM D751 |
24.5 oz/yd2
64.25 in
|
831 g/m2
163 cm
|
| Grab Tensile |
ASTM D751 |
400/340 lb |
1780/1513 N |
| Strip Tensile |
ASTM D751 |
270/230 lb/in |
240/205 daN/5 cm |
| Trapezoid Tensile |
ASTM D5587 |
90/85 lb |
399/377 N |
| Adhesion |
ASTM D751 |
12 lb/in |
5.4 daN/5 cm |
Low Temperature
|
ASTM D2136
|
1 in mandrel -40°F
Pass |
2.5 cm mandrel -40°C
Pass |
Hydrostatic Resistance
|
ASTM D751
Procedure A |
550 psi
|
3.80 MPa
|
| Burning Characteristics |
CA 1237 SM WL |
Pass |
|
| |
ASTM E84 |
Pass |
|
| |
UBC31-1 |
Pass |
|
| |
Can/ULC-S 109-M87 |
Pass |
|
| |
NFPA 701-99 TM #1 |
Pass |
|
| |
NFPA 701-99 TM #2 |
Pass |
|
|